Helixis AI - Clinical Intelligence & Health Platform
Helixis Platforms & SubsystemsHelixis Health Platform · Clinical Pathology & Radiology

Automated test verified · CI3 Diagnostics Pipeline

Diagnostics, Laboratory & Imaging (LIS / RIS)

Closed-loop diagnostic workflows from physician order and payment gating to barcoded specimen custody, analyzer verification, and Patient 360 projection.

Diagnostic errors and revenue leakage happen when laboratory orders, specimen collection, analyzer outputs, and clinical charts live in separate silos. Helixis Health Platform unifies LIS and RIS workflows into a single event-sourced pipeline with strict specimen chain of custody and pathologist verification.

From the moment a clinician orders a Complete Blood Count (CBC), metabolic panel, or CT scan, Helixis Health Platform tracks every state transition. The system enforces configurable billing gates for outpatient diagnostics, generates specimen barcodes, isolates external analyzer communication behind validated HL7/ASTM/DICOMweb adapters, and routes verified critical values straight to the ordering physician.

Domain Capabilities

Engineered around clinical authority and operational truth.

Every action inside Diagnostics & LIS is validated at the server boundary and linked to the patient’s longitudinal record.

01 · CAPABILITY

Closed-Loop Specimen Chain of Custody

Tracks phlebotomy collection, tube barcoding, lab reception, centrifugation, analyzer loading, and archival storage with full actor and timestamp attribution.

02 · CAPABILITY

Instrument & Analyzer Adapter Isolation

Receives raw hematology, biochemistry, and imaging feeds via HL7 v2 ORU and DICOMweb without allowing external instruments to directly mutate clinical records.

03 · CAPABILITY

Pathologist & Radiologist Sign-Off Gate

Preliminary analyzer values remain distinct from finalized clinical reports until a credentialed pathologist or radiologist reviews and digitally signs the result.

04 · CAPABILITY

Investigation Intelligence & Trend Deltas

Automatically projects finalized lab results into the Patient 360 longitudinal graph, highlighting abnormal flags, panic thresholds, and multi-month trajectories.

Operational Workflow

End-to-end governed execution path.

How clinical, technical, and financial actors move work through Diagnostics & LIS without paper workarounds or silent state drift.

01

Attending Physician & Billing

Clinical Order & Tariff Gate

Physician orders diagnostic investigations inside the encounter; for OPD visits, billing settlement automatically unlocks the phlebotomy collection queue.

02

Phlebotomy & Central Lab Reception

Barcoded Phlebotomy & Accessioning

Specimen is drawn, barcoded against the patient wristband, and accessioned into the laboratory information subsystem.

03

Automated Analyzer & Lab Technologist

Analyzer Processing & Quality Control

Instrument adapter ingests assay outputs, checks Westgard QC rules, and flags delta anomalies against the patient’s prior baseline.

04

Consultant Pathologist / Radiologist

Pathologist Release & Clinical Projection

Signed results immediately transition the Patient 360 InformationState from PENDING to CONFIRMED and release any held discharge gates.

Event-Sourced Contract

Canonical events, authority gates & projections.

The client interface never mutates database rows directly. Commands are verified against role and license authority before emitting immutable domain events.

Canonical Domain EventAuthority & Role GateKey Event PayloadDownstream Projection
DiagnosticOrderPlacedLicensed Clinician with Order PrivilegesorderId, encounterId, loincCode, priority (STAT | ROUTINE), clinicalIndicationBilling Charge Queue & Phlebotomy / Radiology Worklist
SpecimenCollectedAndBarcodedPhlebotomist / Lab TechnicianspecimenId, orderId, containerType, collectionSite, collectedAt, collectorIdLab Processing Queue & Patient 360 PENDING InformationState
AnalyzerRawResultIngestedAuthenticated LIS Instrument AdapterspecimenId, analyzerId, rawParameters[], referenceRanges[], flags[]Pathologist Verification Workbench
DiagnosticReportVerifiedCredentialed Pathologist / Radiologist SignaturereportId, orderId, verifiedParameters[], interpretation, criticalAlertFlagPatient 360 CONFIRMED State & Attending Physician Alert Feed
Safety & Invariant Guarantees

How Diagnostics & LIS prevents silent clinical or financial failure

Unverified analyzer output is never presented as a finalized clinical finding.

Amended or corrected lab reports preserve the superseded report in the audit trail (InformationState: SUPERSEDED).

Critical panic values trigger deterministic escalation workflows independent of AI summarization.

Verification & Evidence

HL7 & FHIR Clinical Integration Specification

Inspect the underlying architectural research, repository verification scope, and qualification runbook supporting this subsystem.

Connected Hospital Platform

Explore other Helixis Health Platform subsystems

View all 52 domains overview